Swepco Bituminous & Reflective Coatings
Video | MSDS | Product Brochure | Product DataSwepco Flexshield Roof Coating® Products Information
- Waterproofs, protects and preserves old and new roofs.
- Cold process application is safer and faster.
- Water based formula meets environmental codes.
- Resists blistering because it breathes.
Environmentally friendly waterproofing for concrete, asphalt, asbestos cement & metal roofs.
A black emulsified (water base) liquid asphalt roof coating containing select ingredients and additives. Recommended for use over existing or new smooth or granule-surfaced asphalt, metal, corrugated asbestos cement and bare concrete. Highly resistant to blistering because it has a "breathing" capability which allows trapped moisture to escape right through the coating itself.
DESCRIPTION AND
PURPOSE:
SWEPCO Flex•Shield® Roof Coating is a superior mineral
colloid asphalt emulsion roof coating, manufactured from
premium quality waterproofing asphalt, High Strength Micro
Fibers, a select grade of bentonite and other special chemical and
mineral ingredients which insure a durable product. It is especially
formulated to waterproof, protect and preserve both new
roofs and properly prepared existing roofs. As a maintenance
coating, it is compatible with smooth surface asphalt roofs;
concrete and corrugated asbestos cement roofs; gravel, granule and
other aggregate covered asphalt roofs; granular surfaced roll
roofing roofs; and exposed metal roofs. It is used with other
SWEPCO Roofing Products in a number of applications for both
roof maintenance and new roofing.
It doesn’t just waterproof, it
makes roofs last longer.
SWEPCO Flex•Shield® Roof Coating is more than just a
waterproofer for industrial and commercial roofs. It’s an economical
protective coating. In addition to waterproofing both new and existing roofs, it protects
costly roof membranes, insulation and decks from deterioration.
Applied in time and as an integral part of a planned
maintenance program or a new roof system, it makes both old
and new roofs last longer by protecting them from moisturepenetration, oxidation and
erosion, the most common causes of roof failure.
OUTLASTS CONVENTIONAL COATINGS
SWEPCO Flex•Shield® Roof Coating outperforms conventional
asphalt waterproofing materials in a number of ways, the most important of which is service life. Flex•Shield® Roof
Coating is a modern mineral colloid emulsion coating with superior weathering characteristics.
Its outstanding resistance to oxidation slows down the natural
aging process and makes it last longer. It waterproofs without
blistering or peeling because its unique film doesn’t trap damaging
moisture. And it has superior natural resistance to cracking,
alligatoring and erosion. These natural performance features create a protective
coating which lasts longer than most types of waterproofing coatings.
SUPERIOR FIRE RESISTANCE
In industrial and commercial fire
situations, SWEPCO Flex•Shield®
“chars in place” instead of
melting, running, spreading the
flame and feeding the fire. It meets or exceeds the American
Society of Testing & Materials Specification D-1227, Type IV,
and Canadian Government Specification 37-GP-28M.
EASIER, FASTER, LESS COSTLY APPLICATION
Application of SWEPCO
Flex•Shield® Roof Coating is
easy, fast and simple. It’s a “cold process” coating which
means that, unlike “hot-mop”
asphalts, it is applied just as it
comes from the container. Ease
of application means reduced
costs for contract labor. But ease of application can mean even
more substantial savings for
those who prefer to take full
advantage of it by having their
own maintenance staff handle
application. General maintenance
personnel can get professional
results by following the
simple instructions furnished on
every container.
REDUCES ROOF MAINTENANCE COSTS
SWEPCO Flex•Shield® Roof
Coating’s outstanding thermal
stability, weathering and fire
resistance and compatibility with
modern energy efficient reflective
coatings make the use of
gravel unnecessary. As a result,
it eliminates many of the problems
and much of the cost
associated with typical gravel surfaced roofs. Periodic inspection
becomes a task measured in minutes instead of hours. And,
when
maintenance does finally
become necessary, it costs lessbecause it takes less time. Because
it’s formulated with
maintenance in mind,
Flex•Shield® Roof Coating
insures continued savings well
beyond its own service life.
ELIMINATES ROOFING POLLUTION
SWEPCO Flex•Shield® Roof
Coating has another important
advantage. It won’t pollute the
environment. It’s not heated
during application like “hotmop” asphalts, so there are no
foul odors polluting the area.
And it doesn’t contain the heavy
concentrations of petroleum
solvents used in still other types of coatings. Besides making
other products more expensive,
these solvents pollute the environment. And because
Flex•Shield® Roof Coating
doesn’t contain these harmful
solvents, it takes less petroleum
to make ... up to 30% less, in fact.
GENERAL DATA:
TYPICAL PHYSICAL PROPERTIES
Viscosity, Stormer, @ 77°F (25°C), KU, ASTM D-562 ......................................... 120-140
Specific Gravity, @ 60°F (15.5°C), ASTM D-70 ........................................................... 1.02
Unit Weight, lb/gal, ASTM D-70 ...................................................................................... 8.5
Unit Weight, kg/liter, ASTM D-70 ................................................................................. 1.02
Drying Time, to Touch, hours ............................................................................................ 2-4
Drying Time, Through, hours ............................................................................................. 24
Flash Point ............................................................................... Water Base - Not Applicable
Wet Film Thickness, 1 gal/100 ft2, mil .............................................................................. 16
Wet Film Thickness, 1 liter/m2, mm .................................................................................... 1
Dry Film Thickness, 1 gal/100 ft2, mil ................................................................................. 8
Dry Film Thickness, 1 liter/m2, mm ................................................................................. 0.5
Color, Wet .......................................................................................................................Brown
Color, Cured ..................................................................................................................... Black
Odor .............................................................................................................................. Pungent
TYPICAL PERFORMANCE PROPERTIES
Workability .................................................. Permits application by brush, roller or spray
Flexibility, @ 32°F (O°C), ASTM D-2939 ...................................... No cracking or flaking
Heat Resistance, @ 212°F (100°C), ASTM D-2939 ... No blistering, sagging or slipping
Adhesion to Dry or Wet Surfaces, ASTM D-1227 ................................................ Excellent
Direct Flame Test, ASTM D-2939 ................................................................. Chars in place
Accelerated Weathering, hours, ASTM D-G53 ........................................................ 4,000*
Peeling and Chipping .................................................................................................. None
Erosion ........................................................................................................................... Slight
Water Penetration ........................................................................................................ None
Chalking ........................................................................................................................ Slight
Storage Stability ............................................................................................................. 1 Year
......... (may develop some water separation which can be compensated for by mixing)
*NOTE: This is roughly equivalent to eight years of exposure to ultra-violet radiation, heat and moisture
generally encountered in field service.
TYPICAL CHEMICAL PROPERTIES
Non Volatile, % wt, ASTM D-2939 ................................................................................... 50
Volatiles, % wt, ASTM D-2939 ........................................................................................... 50
Asphalt Portion Soluble in CS2, % wt, ASTM D-4 ....................................................... 99.9
Resistance to Mild Acid or Alkali .................................................................................. Good
Resistance to Water ................................................................................................... Excellent
Resistance to Petroleum Solvents ................................................................................... Poor
Asphalt Contents, % wt, ASTM D-4 ................................................................................. 45
Stabilizers, % wt, ASTM D-4 ................................................................................................ 5
APPLICABLE SPECIFICATIONS
ASTM D-1227, Type IV
Canadian Government Specification 37-GP-28M
Outstanding Benefits
It doesn't just waterproof, it makes roofs
last longer.
It outlasts conventional coatings.
It waterproofs without blistering.
It has greater fire resistance.
It's easier, faster and less costly to apply.
It reduces roof maintenance costs.
It eliminates roofing pollution.
Application Information
IMPORTANT: SWEPCO Flex•Shield®
Roof Coating is a premium-quality,
asphalt emulsion coating designed to
waterproof, protect and preserve both
new and properly prepared old smooth
surface asphalt roofs; concrete and
corrugated asbestos cement roofs;
gravel, granule or other aggregate
covered asphalt roofs; granular surfaced
roll roofing roofs; and exposed metal
roofs. It is not designed for use on nor
should it be applied directly to insulation,
coal tar pitch roofs, wood surfaces,
composition shingles or any other form
of rigid shingles, such as wood, slate,
cement, clay or asbestos-cement
shingles. SWEPCO Flex•Shield® Roof
Coating is used in a variety of applications
both with and without a reinforcing
mat. Instructions provided here
relate to this product only. For complete
instructions refer to the appropriate
installation brochure or system specification
sheet before using.
PREPARATION:
The roof surface
should be sound and should drain
water freely. Because standing water
accelerates deterioration of all asphalt
roofing products, every effort should be
made to isolate and correct the causes of
any standing water or ponding on the
roof. A minimum slope of 1/4 in. per
foot (2%) is recommended. When this is
not possible, SWEPCO Products can still
be applied and will provide temporary
protection for such areas. However, it must be understood that performance of
SWEPCO Products cannot be guaranteed
in any area of the roof subject to
standing water. No area should be exposed to continually leaking equipment.
Loose gravel, granules or aggregate must be removed. The
surface must then be thoroughly cleaned free of all dust, dirt and loose
debris. All blisters, cracks, split seams and other surface irregularities should
be repaired with SWEPCO Flex•Shield®Patching Compound and Heavy Duty
Patching Fabric. The surface may then require priming with SWEPCO
Flex•Shield® Primer, depending upon
the system being installed. (For complete
information, see instruction labels
for SWEPCO Flex•Shield® Patching
Compound, Heavy Duty Patching
Fabric and Flex•Shield® Primer and the
appropriate SWEPCO installation
brochure or system specification sheet.)
APPLICATION: SWEPCO Flex•Shield®
Roof Coating is applied straight from
the container with soft bristle roofing
brushes, squeegees or airless spray
equipment at the minimum coverage
rate recommended below. It requires no
heating or thinning, but will require
mixing if it has been stored for some
time. To insure proper application
during hot weather, the roof surface should be dampened lightly and
uniformly with clean water prior to
application. Do not allow puddles to
form and do not dampen such a large
area that the water evaporates before
application takes place. (For specific
recommendations concerning spray
application, contact Swepdri International.)
APPLICATION PRECAUTIONS:
SWEPCO Flex•Shield® Roof Coating
will freeze. It should not be applied in
temperatures below 40°F (4°C). BECAUSE
IT IS AN “EMULSION” TYPE ASPHALT PRODUCT, SWEPCO
FLEX•SHIELD® ROOF COATING CAN “WASH-OFF” IF SUBJECTED TO RAIN
OR HEAVY DEW BEFORE IT IS
SUFFICIENTLY CURED. It should
therefore not be applied in rainy
weather or if rain is expected before
complete curing can take place. In
sunny conditions, curing normally takes
only 24 hours, but in cold, cloudy,
damp, foggy or humid conditions,
curing can take much longer. Safestapplication is on a warm sunny day
with no forecast of rain for 24-48
hours. Avoid thick build-ups or
puddles of the coating as this can
cause shrinkage cracking.
MINIMUM COVERAGE RATES:
Minimum recommended coverage
rates vary from a low of 1.75 gal.
per 100 sq. ft. (.71 liter/m2) to a
high of 9 gal. per 100 sq. ft. (3.68
liter/m2) in two coats, depending
on the type of surface and type of
system being installed. Consult the
appropriate SWEPCO Roof System
installation instructions for required minimum coverage rates.
CURING:
In sunny conditions,
SWEPCO Flex•Shield® Roof
Coating normally cures within 24
hours of application, but in cold,
cloudy, damp, foggy or humid conditions, curing can take much
longer. It should be allowed to cure
for a minimum of 14 days before
application of other protective or
reflective coatings such as SWEPCO
Aluminum Roof Shield, SWEPCO
White Acrylic Coating or SWEPCO
White Roof Shield. The surface will
become tacky on warm days beyond this 14-day minimum
curing period. For this reason,
application of reflective coatings
should only be attempted in early
morning hours or on cooler days
when surface tackiness is at a minimum.
STORAGE:
SWEPCO Flex•Shield®
Roof Coating has a minimum shelf life
of one year provided containers are kept
tightly sealed and protected against
high temperatures. This product will
freeze and should be stored where
temperatures will not drop below 35°F
(2°C). Storage beyond six months may
cause the product to thicken. In such
cases, the product should be diluted
with clean potable water at a rate not to
exceed one part water to six parts
coating. Dilute slowly and mix thoroughly,
adding only enough water to
permit application at the proper
coverage rate. Mechanical mixing is
highly recommended. In no event
should the product be diluted beyond
the maximum dilution rate of 1:6 as this
will void any guarantee to which the
product may be subject.
ADDITIONAL INFORMATION:
For additional information or recommendations,
contact: Swepdri International
SAFETY PRECAUTIONS:
Avoid contact with eyes. Avoid prolonged or
repeated contact with skin. Wear
protective goggles, gloves and clothing.
Avoid prolonged breathing of vapors.
Use with adequate ventilation or
approved respirators in confined areas.
Do not take internally. Store and use
away from heat, open flame or spark
sources. Close container tightly after
each use. Do not transfer to unlabeled
or breakable containers. Use only for
purposes intended. Keep out of reach of
children.
EFFECTS OF OVEREXPOSURE:
Contact with eyes or prolonged or
repeated contact with skin can cause
irritation and inflammation. Prolonged
breathing of vapors can cause respiratory
difficulty, dizziness, headache,
nausea, irritation of nose or throat,
drowsiness, blurred vision and coma.
Ingestion can expose person to an order
of oral toxicity; aspiration into lungs can
cause serious injury or death.
FIRST AID PROCEDURES:
Eye
Contact - Flush with water for 15
minutes. If pain or redness persists, seek
medical attention immediately. Skin
Contact - Wash with soap and water
after wiping off excess material. If
irritation persists, seek medical attention.
Inhalation - Remove to fresh air.
If breathing difficulty persists, give
oxygen or resuscitate and SEEK
MEDICAL ATTENTION IMMEDIATELY.
Ingestion - Induce vomiting. As
vomiting occurs, keep head below hips
to prevent aspiration. SEEK MEDICAL
ATTENTION IMMEDIATELY.
PHYSICAL EMERGENCY PROCEDURES:
If ignited, extinguish with CO2
or dry chemicals. Water or foam may
cause frothing. Water may be used to
keep containers cool or flush spills away
from area of involvement.
Consult Material Safety Data Sheet
(MSDS) for this product or call Southwestern
Petroleum Corporation at (817)
332-2336 for further health and safety
information.
Note: See Product Container Labels, Product